HANS SOLAR's Off Grid MPPT Solar PCU (Power Conditioning Unit) is an intelligent integrated system of Solar MPPT Charger, Grid Charger, Offline Inverter. We use innovative MPPT algorithm in our Solar Off-Grid PCU that can simultaneously run the load and charge the battery while extracting maximum power from Solar. Suitable for standard Lead-Acid Batteries, as well as flooded, sealed and Lithium type. Our Solar Off-Grid MPPT PCU stand apart from the rest because of their high-quality design and multiple features we have packed into it to make your life easier .
Technical Specification
MODELS/RATINGS
RATINGS |
1KVA COPPER |
1KVA |
2KVA |
2.5KVA COPPER |
3KVA |
5KVA |
5KVA |
7.5KVA |
7.5KVA |
10KVA |
10KVA |
15KVA |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OPERATING DC VOLTAGE | 12V | 24V | 24V | 24 | 48V | 48V | 96V | 96V | 120V | 120V | 180V | 240V |
MAX SPV SUPPORTED | 1KW | 1KW | 2KW | 2.5KW | 3KW | 5KW | 5KW | 7.5KW | 7.5KW | 10KW | 10KW | 15KW |
PV VOC | 18-45V | 36-90V | 36-90V | 36-90V | 72-180V | 72-180V | 144-360V | 144-360V | 180-450V | 180-450V | 270-450V | 360-600V |
OUTPUT VOLTAGE | 230V +/-2% | |||||||||||
OVERLOAD AMPS | 3.6A | 3.6A | 7A | 8.7A | 10.5A | 17.4A | 17.4 | 26A | 26A | 34.8A | 34.8A | 52.2A |
OVERLOAD WATTAGE | 800W | 800W | 1.6KW | 2KW | 2.4KW | 4KW | 4KW | 6KW | 6KW | 8KW | 8KW | 12KW |
MPPT Based Charge Controller
Switching Element
IGBT
Controller
Digital Signal Processor dsPIC
Efficiency
> 95%
Battery Charging Stages
5 (Softstart, Boost, Absorbtion, Float, Equalise)
Battery
Low Cut Off / Recovery
10.5V / 11.5V (Per Battery) +/- 2%
Low Cut Off Alarm
10.7V (Per Battery) +/- 2%
High Cut Off / Recovery
15.5V / 15.0V (Per Battery) +/- 2%
Boost Charging Voltage by Grid (Tubular)
14.5V (Per Battery) +/- 2%
Boost Charging Voltage by Grid (SMF)
+/- 2%
Charging Current by Grid
10A +/- 2%
Output (Inverter)
Output @ No Load
230V +/- 2% 1 Phase 3 Wire P,N,E
Output Frequency
50 Hz +/- 2%
Output Low/Shortcircuit Retry
1 Time
No Load Current (NLC)
2%
Display Parameters
Display
16X2 Display (1KVA Models)/ 20X4 LCD Alphanumeric (2KVA Above)
Inverter Display
Voltage, Current, Power, Energy and Frequency
Solar Display
Voltage, Current, Power, Energy Generated (Cumulative)
Mains Grid Display
Voltage and Frequency
Battery Display
Voltage and Charging Current
Status / Fault Display
Inverter Status, Mains Status, Charger Status, Battery Status, Charging Status, Solar Status, Solar Charger Status
Inverter
Switching Element
MOSFET & IGBT
Output Waveform
Digital Filtered Pure Sine Wave
Overload Retry
3 Times
Switch
System On/Off, Four Micro Switches (Enter, Back, Up, Down) to access and navigate through the settings MENU. Download the detailed brochure to understand all settings.
Indication
UPS, Mains, Charging (Solar & Mains) , Battery, Overload
Alarm
Inverter On/Off, Mains Charger On, Solar Charger On, Overload, Battery Low
Protection
Overload, Short circuit, Over voltage, Under Voltage, Mains Surge and Transient by MOV and Varistors, Reverse Polarity of Battery, Over Temperature, Solar Reverse, SPV Surge
Cooling
Forced Air Cooling (Temperature Controlled)
Remote Monitoring
RS232, RS485, GSM / GPRS Remote Monitoring (Optional)
Operating Temperature
0-50 Degree Celsius
NOTE: Due to continuous improvement in the product and design. These specification may deviate a bit from the actual product, but only in a better way.