SOLAR OFF GRID MPPT PCU

 Solar OFF Grid MPPT PCU

CLEAN & GREEN SOLAR POWER BACKUP

HANS SOLAR's Off Grid MPPT Solar PCU (Power Conditioning Unit) is an intelligent integrated system of Solar MPPT Charger, Grid Charger, Offline InverterWe use innovative MPPT algorithm in our Solar Off-Grid PCU that can simultaneously run the load and charge the battery while extracting maximum power from Solar. Suitable for standard Lead-Acid Batteries, as well as flooded, sealed and Lithium type. Our Solar Off-Grid MPPT PCU stand apart from the rest because of their high-quality design and multiple features we have packed into it to make your life easier .

Technical Specification

MODELS/RATINGS

RATINGS

1KVA COPPER

1KVA

2KVA

2.5KVA COPPER

3KVA

5KVA

5KVA

7.5KVA

7.5KVA

10KVA

10KVA

15KVA

OPERATING DC VOLTAGE 12V 24V 24V 24 48V 48V 96V 96V 120V 120V 180V 240V
MAX SPV SUPPORTED 1KW 1KW 2KW 2.5KW 3KW 5KW 5KW 7.5KW 7.5KW 10KW 10KW 15KW
PV VOC 18-45V 36-90V 36-90V 36-90V 72-180V 72-180V 144-360V 144-360V 180-450V 180-450V 270-450V 360-600V
OUTPUT VOLTAGE 230V +/-2%                      
OVERLOAD AMPS 3.6A 3.6A 7A 8.7A 10.5A 17.4A 17.4 26A 26A 34.8A 34.8A 52.2A
OVERLOAD WATTAGE 800W 800W 1.6KW 2KW 2.4KW 4KW 4KW 6KW 6KW 8KW 8KW 12KW

MPPT Based Charge Controller

 
Switching Element
IGBT

Controller
Digital Signal Processor dsPIC

Efficiency
> 95%

Battery Charging Stages
5 (Softstart, Boost, Absorbtion, Float, Equalise)

Battery
Low Cut Off / Recovery
10.5V / 11.5V (Per Battery) +/- 2%

Low Cut Off Alarm
10.7V (Per Battery) +/- 2%

High Cut Off / Recovery
15.5V / 15.0V (Per Battery) +/- 2%

Boost Charging Voltage by Grid (Tubular)
14.5V (Per Battery) +/- 2%

Boost Charging Voltage by Grid (SMF)
+/- 2%

Charging Current by Grid
10A +/- 2%

Output (Inverter)
Output @ No Load
230V +/- 2% 1 Phase 3 Wire P,N,E

Output Frequency
50 Hz +/- 2%

Output Low/Shortcircuit Retry
1 Time

No Load Current (NLC)
2%

Display Parameters
Display
16X2 Display (1KVA Models)/ 20X4 LCD Alphanumeric (2KVA Above)

Inverter Display
Voltage, Current, Power, Energy and Frequency

Solar Display
Voltage, Current, Power, Energy Generated (Cumulative)

Mains Grid Display
Voltage and Frequency

Battery Display
Voltage and Charging Current

Status / Fault Display
Inverter Status, Mains Status, Charger Status, Battery Status, Charging Status, Solar Status, Solar Charger Status

Inverter
Switching Element
MOSFET & IGBT

Output Waveform
Digital Filtered Pure Sine Wave

 
Overload Retry
3 Times

Switch
System On/Off, Four Micro Switches (Enter, Back, Up, Down) to access and navigate through the settings MENU. Download the detailed brochure to understand all settings.

Indication
UPS, Mains, Charging (Solar & Mains) , Battery, Overload

Alarm
Inverter On/Off, Mains Charger On, Solar Charger On, Overload, Battery Low

Protection
Overload, Short circuit, Over voltage, Under Voltage, Mains Surge and Transient by MOV and Varistors, Reverse Polarity of Battery, Over Temperature, Solar Reverse, SPV Surge

Cooling
Forced Air Cooling (Temperature Controlled)

Remote Monitoring
RS232, RS485, GSM / GPRS Remote Monitoring (Optional)

Operating Temperature
0-50 Degree Celsius
 

NOTE: Due to continuous improvement in the product and design. These specification may deviate a bit from the actual product, but only in a better way.